SCI Scandicrafts Air Cleaner A2840 R User Guide

Fresh Air, Surface and Fabric Regenerator  
Air-Surface Sanitizer  
OWNER’S MANUAL  
MORE THAN JUST  
AIR PURIFIERS...  
THEY HELP  
TO SANITIZE  
BOTH THE AIR  
AND SURFACES  
INCLUDES:  
• INSTALLATION  
• OPERATION  
• SPECIFICATIONS  
• FEATURES  
• MAINTENANCE  
• 10 PURIFICATION  
STEPS TO A  
HEALTHY HOME  
IMPORTANT:  
SAVE THIS BOOKLET!  
A2840/R  
 
EdenPURE™ G-7  
READ AND SAVE THESE INSTRUCTIONS  
VERY IMPORTANT:  
• Read this manual carefully before operating.  
• Do not operate unit if unfamiliar with this manual.  
• Keep this manual for future reference.  
SAFETY WARNINGS  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, BASIC PRECAUTIONS SHOULD BE FOLLOWED INCLUDING:  
• Disconnect power cord before performing any maintenance or service.  
• The rear of the unit should always have at least one inch of open area to allow  
unrestricted airflow.  
• To prevent injury, be sure the power cord is not accessible to small children.  
• The supplied power voltage must be uniform with the appliance’s permitted voltage  
indicated on the back of the unit. Appliances with 110v/60Hz cannot be used with a  
220v/50 Hz power supply.  
• Only connect to a properly grounded 3 prong circuit receptacle.  
• Do not alter the cord or any other part of the unit.  
• Do not use with a broken ceramic plate.  
• Do not look directly at the UVC bulb while it is operating.  
• Do not use outdoors or on wet surfaces.  
• Do not use with a damaged cord or plug.  
• Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.  
• Do not operate the unit in areas where flammable, combustible products, or where  
vapors may be present.  
• Do not handle the plug or appliance with wet hands.  
• Supervision is necessary when appliance is operated near children.  
• Turn off all controls before unplugging unit from outlet.  
• If appliance is not working as it should, has been dropped, damaged, left outdoors, or  
dropped into water, contact the sales representative where you purchased the unit or  
return it to your local service center.  
2
 
FEATURES  
·
·
·
·
QUIET FIVE SPEED FAN  
ADJUSTABLE 24-HOUR CLOCK  
ADJUSTABLE POWER OFF TIMER  
ADJUSTABLE PURIFIER CONTROL (USED FOR RAPID ODOR REMOVAL AND  
SURFACE STERILIZATION)  
·
ANION - NEGATIVE ION GENERATOR (NEGATIVE IONS CAUSE THE FLOATING  
PARTICULATES TO CLING TOGETHER, FORMING A MASS WHICH DROPS  
THEM TO THE FLOOR TO BE SWEPT UP)  
·
·
STERILIZE (UVC LIGHT HELPS REDUCE AIRBORNE GERMS AS THEY PASS  
THROUGH THE UNIT)  
HELPS REDUCE SMOKE AND ODORS FROM YOUR HOME, OFFICE, CAR, BOAT,  
RV, ETC...  
·
·
·
·
·
·
·
·
·
REDUCES MOLD, MILDEW AND BACTERIA  
REPLACEABLE UV LAMP  
REMOTE CONTROL OR MANUAL OPERATION VIA FRONT PANEL CONTROLS  
USER INTERFACE DISPLAY  
MAINTENANCE REMINDERS  
WASHABLE PURIFICATION PLATE  
WASHABLE PHOTO-CATALYTIC PROCESS SCREEN  
WASHABLE PRIMARY FILTER  
SLEEP MODE (DISABLES MOST OF THE DISPLAY LIGHTS, BUT UNIT CONTINUES  
TO OPERATE)  
·
·
IMPROVES INDOOR AIR QUALITY  
USES STANDARD HOUSEHOLD CURRENT  
INSPECTION & INSTALLATION  
1. Remove unit from shipping carton.  
2. Check for shipping damage and loose or broken parts.  
3. Remove any protective materials from the outside of the unit.  
4. Read Owner’s Manual thoroughly prior to operating or servicing the unit.  
5. Insert the battery into the remote by sliding the battery compartment open and placing  
the battery with the positive side (+) facing up.  
6. Open the Primary Filter by removing the four corner screws and remove all protective  
materials from the inside of the unit, i.e. tape used to hold the Catalytic Screen and/or  
UV Lamp in place.  
7. Make sure Catalytic Screen is secure. (Refer to: “GENERAL MAINTENANCE”, page 5)  
8. Make sure the purification plate is secure and fully inserted in its slot. (Refer to: Page 6  
Diagram B)  
9. Reinstall the Primary Filter and any other temporarily removed parts before continuing.  
10. Determine placement location for the unit. We recommend placing it up higher if  
possible. A securely fastened wall shelf would be an ideal location.  
11. Plug the unit into a 3 prong grounded circuit receptacle.  
3
 
GENERAL OPERATION  
The unit can be operated using either the wireless remote or the front control panel.  
OFF  
ON  
1. On the rear of the purifier, switch the master power to the “on” position (the front display  
will light up).  
2. Press the ON/OFF button on the front of purifier to power on the unit. The fan will start.  
3. Press the FanL and FanM buttons to adjust the airflow speed to your desired level.  
4. Press the PurifyL and PurifyM buttons to set the purifier setting from Stage 1 through  
Stage 5 to accommodate your desired level.  
5. Press the Sterilize button to operate the UVC and Photo Catalyst sanitize feature.  
Press the Sterilize button again to stop its operation. The UVC bulb will produce a  
light blue glow on the inside of the unit when this feature is on. Note: Do not look  
directly at the UVC Bulb while it is operating.  
6. Press the Anion button to turn on the negative ion generator. Press the Anion button  
again to stop the negative ion generator function.  
Sleep Button  
Press the Sleep button to use the screen saving mode. This will turn most of the  
display lights off. Press any button on the front panel to deactivate the sleep mode.  
The working mode of Anion, Purify, Sterilize, and Fan Speed will not change while in  
sleep mode. If the timer function is set to turn the power off at a set time, do not use  
the sleep function. The timer will only deactivate the sleep mode instead of shutting  
down the unit if the sleep mode is on.  
Time/Set Button  
Read these instructions thoroughly before setting the time.  
*** After 8-10 seconds of inactivity, the clock will be set or you will have to start the process again. ***  
The clock is a 24-hour clock; 13:00 would be 1:00 p.m.  
To set the current time:  
1. Press the Time/Set button twice. “Time” will blink on the display.  
2. The PurifyL and PurifyM buttons adjust the hours. The FanL and FanM buttons  
adjust the minutes.  
To set the power off timer:  
1. While the unit is operating, press the Time/Set button once. Time/Set” will blink on  
the display.  
2. The PurifyL and PurifyM buttons adjust the hours. The FanL and FanM buttons  
adjust the minutes.  
Remote  
Sterilizer Feature  
Purifier Feature (5 Stages)  
Anion Feature  
Power Switch Time  
Fan Speed  
Operating Display  
Operating Buttons  
4
 
GENERAL MAINTENANCE  
UNPLUG THE UNIT BEFORE PERFORMING ANY MAINTENANCE PROCEDURES  
Recommended Monthly Maintenance  
• Clean the Primary Filter  
• Clean the Purifier Plate  
• Clean the Catalytic Screen  
PRIMARY FILTER & CATALYTIC SCREEN CLEANING  
You have three options to clean the Primary filter and the Catalytic Screen:  
1. When visibly dirty or after 30 days, remove the primary filter and the catalytic screen  
from the unit. With a hand-held vacuum, remove the heavy particulates from both  
filters. This method will extend the life of the filters and ensure proper function of the  
catalytic screen.  
2. If vacuuming does not clean the filter sufficiently, remove the primary filter and the  
catalytic screen from the unit and wash them in warm water. Brush gently with a  
toothbrush to remove particulates. Allow to dry thoroughly before re-installing.  
NOTE: Do not use soap because it could damage the filters.  
3. If a replacement or additional filter and/or catalytic screen are needed, contact the  
closest dealer.  
CLEANING THE PURIFICATION PLATE  
1. Remove the Purification Plate (see Purification Plate and Catalytic Screen Removal below).  
2. Wash the Purification Plate with about 1 drop of mild dish soap (per side) and a toothbrush.  
3. Use the toothbrush to make small circular motions over all of the metal mesh areas.  
Be careful not to drop or break the Purification Plate while cleaning.  
4. Rinse with water and allow it to air dry completely before reinstalling.  
PRIMARY FILTER REMOVAL  
1. Unplug the power to the unit.  
2. Unscrew the four rear corner screws from the Primary filter and pull the filter handle  
to remove. Refer to Diagram A  
3. After servicing Primary filter, place it back in its original position and re-install the  
four corner screws.  
PURIFICATION PLATE AND CATALYTIC SCREEN REMOVAL  
1. Remove Primary filter.  
2. Carefully remove the Purification Plate pulling it straight out. This is an ideal time to  
clean the Purification Plate. Refer to Diagram B.  
3. Gently pull the Catalytic Screen handle to remove it for cleaning. Refer to Diagram C.  
4. After servicing Catalytic Screen, place it back in its original position by placing the  
bottom of screen in first.  
5. Carefully re-insert the Purification Plate into its original position. Make sure the  
Purification Plate is fully inserted.  
6. Place the Primary filter back in its original position and re-install the four corner screws.  